{"product_id":"solis-16kw-1ph-hybrid-inverter","title":"Solis 16kW 1ph Hybrid Inverter","description":"\u003ch1 dir=\"ltr\"\u003eSolis S6-EH1P16K03-NV-YD-L | Solarator Series 16kW Single-Phase Hybrid Inverter\u003c\/h1\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eUninterrupted power, even in areas with grid instability.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003ePart of Solis's Solarator Series, the S6-EH1P16K03-NV-YD-L is a single-phase, low-voltage energy storage inverter built to operate seamlessly with a generator — delivering reliable power even where the grid isn't. It supports PV input up to 160% of its rated DC power, switches between on\/off-grid in under 10ms, and handles 200% overload for 10 seconds off-grid for stable startup of motors, pumps, and air conditioners.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWhy Choose This Inverter\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximized Solar Utilization\u003c\/strong\u003e — Supports PV input up to 160% of the inverter's rated DC power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuture-Ready PV Compatibility\u003c\/strong\u003e — Handles up to 20A PV input current for higher-power PV modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Off-Grid Startup\u003c\/strong\u003e — 200% overload for 10s in off-grid mode for stable motor, pump, and AC startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Switching\u003c\/strong\u003e — On\/off-grid switching in under 10ms for uninterrupted power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Battery Compatibility\u003c\/strong\u003e — Works with any battery between 40V and 60V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrid-Tied Flexibility\u003c\/strong\u003e — Supports existing PV grid-tied connections for export control and off-grid use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator Ready\u003c\/strong\u003e — Multiple generator connection methods with auto control for flexible deployment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable System\u003c\/strong\u003e — Supports up to 6 units in parallel for greater capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Load Management\u003c\/strong\u003e — Extends backup time for critical loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomizable Backup\u003c\/strong\u003e — Adjustable battery backup level for uninterrupted power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV-Only Off-Grid Operation\u003c\/strong\u003e — Reduces upfront costs by skipping the need for a battery in some setups\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolisCloud Platform\u003c\/strong\u003e — Smart remote control, AI optimization, and instant troubleshooting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge 7\" Touchscreen\u003c\/strong\u003e — Industrial-grade display for user-friendly local operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarsh-Condition Ready\u003c\/strong\u003e — IP66 ingress protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003eKey Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Max. PV Array Size\u003c\/td\u003e\n\u003ctd\u003e32 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Usable PV Input Power\u003c\/td\u003e\n\u003ctd\u003e25.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Input Voltage\u003c\/td\u003e\n\u003ctd\u003e550 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range\u003c\/td\u003e\n\u003ctd\u003e80–520 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Current\u003c\/td\u003e\n\u003ctd\u003e40A \/ 40A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Number \/ Max. Input Strings\u003c\/td\u003e\n\u003ctd\u003e3 \/ 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLi-ion \/ Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range\u003c\/td\u003e\n\u003ctd\u003e40–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge\/Discharge Current\u003c\/td\u003e\n\u003ctd\u003e290 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication (Battery)\u003c\/td\u003e\n\u003ctd\u003eCAN \/ RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power (Grid)\u003c\/td\u003e\n\u003ctd\u003e16 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Apparent Output Power\u003c\/td\u003e\n\u003ctd\u003e16 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Grid Voltage\u003c\/td\u003e\n\u003ctd\u003eL\/N\/PE, 220V \/ 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Grid Output Current\u003c\/td\u003e\n\u003ctd\u003e72.7A \/ 69.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;0.99 (0.8 leading – 0.8 lagging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power (Back-up)\u003c\/td\u003e\n\u003ctd\u003e16 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Apparent Output Power (Back-up)\u003c\/td\u003e\n\u003ctd\u003e2× rated power for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack-up Switch Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10ms (single); \u0026lt;20ms (parallel, up to 6 units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Passthrough Current\u003c\/td\u003e\n\u003ctd\u003e90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Efficiency\u003c\/td\u003e\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEU Efficiency\u003c\/td\u003e\n\u003ctd\u003e97.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBAT Charged by PV \/ AC Max. Efficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;94.9% \/ \u0026gt;94.33%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Discharged Efficiency\u003c\/td\u003e\n\u003ctd\u003e93.51%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e459 × 845 × 313 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e55.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Topology\u003c\/td\u003e\n\u003ctd\u003eNon-isolated (PV), Isolated (Battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-25°C ~ +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Emission (typical)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Concept\u003c\/td\u003e\n\u003ctd\u003eIntelligent redundant fan-cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Operation Altitude\u003c\/td\u003e\n\u003ctd\u003e4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 dir=\"ltr\"\u003eProtection Features\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eSurge protection, output over current protection, insulation resistance monitoring, residual current detection, integrated PV switch, DC reverse-polarity protection (PV only), optional Integrated AFCI 2.0, and anti-islanding protection.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eConnectivity \u0026amp; Interfaces\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eMC4 PV connector, terminal-block battery and AC connections, 7.0\" LCD display with Bluetooth + APP. Standard communication: WiFi + LAN + Bluetooth, CAN-BMS, CAN-Parallel×2, RS485-Meter, RS485, DRM, DI, DO×2. Optional 4G connectivity.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eCertifications\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eNRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, EN50549-1; IEC\/EN 62109-1\/-2, EN 61000-6-2\/-3\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eIdeal For\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eResidential and commercial single-phase solar-plus-storage systems in areas with grid instability — combining generator integration, smart load management, and cloud-based remote monitoring, with the flexibility to scale into a multi-inverter parallel system.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eSpecifications per manufacturer datasheet (Solis Solarator Series S6-EH1P(12-18)K03-NV-YD-L, Single Phase Low Voltage, South Africa Flyer V2.2). Specifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Solis","offers":[{"title":"Default Title","offer_id":43932184346714,"sku":"IN-SO-16K-1PH","price":2650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/6580\/3354\/files\/1748874389830_1cb17347-6ccd-48fb-b7bb-eb01c359e6cb.webp?v=1787921538","url":"https:\/\/siw-zim.co.zw\/products\/solis-16kw-1ph-hybrid-inverter","provider":"Siw-Zim","version":"1.0","type":"link"}