{"product_id":"solis-15kw-3ph-hybrid-inverter","title":"Solis 15kW 3ph Hybrid Inverter","description":"\u003ch1 dir=\"ltr\"\u003eSolis S6-EH3P15K02-NV-YD-L | Solarator Series 15kW Three-Phase Hybrid Inverter\u003c\/h1\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eUninterrupted power for demanding three-phase solar and storage installations.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003ePart of Solis's Solarator Series, the S6-EH3P15K02-NV-YD-L is a three-phase, low-voltage energy storage inverter built to maximize solar utilization and deliver seamless backup power. It supports PV input up to 160% of its rated DC power, switches between on\/off-grid in under 10ms, and handles 200% overload for 10 seconds off-grid — enough to reliably start motors, water pumps, and air conditioners.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWhy Choose This Inverter\u003c\/h2\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximized Solar Utilization\u003c\/strong\u003e — Supports PV input up to 160% of the inverter's rated DC power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuture-Ready PV Compatibility\u003c\/strong\u003e — Handles up to 21A PV input current for higher-power PV modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Off-Grid Startup\u003c\/strong\u003e — 200% overload for 10s in off-grid mode for stable motor, pump, and AC startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Switching\u003c\/strong\u003e — On\/off-grid switching in under 10ms for uninterrupted power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-Phase Unbalanced Output\u003c\/strong\u003e — Each phase supports up to 50% of rated inverter power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC and AC Coupling\u003c\/strong\u003e — Flexibly expand PV, charge batteries, and power loads even off-grid\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator Ready\u003c\/strong\u003e — Multiple generator connection methods with auto control for flexible deployment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable System\u003c\/strong\u003e — Supports up to 6 units in parallel for greater capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Load Management\u003c\/strong\u003e — Prioritization extends backup time for critical loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomizable Backup\u003c\/strong\u003e — Adjustable battery backup level for uninterrupted power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV-Only Off-Grid Operation\u003c\/strong\u003e — Reduces upfront costs by skipping the need for a battery in some setups\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolisCloud Platform\u003c\/strong\u003e — Smart remote control, AI optimization, and instant troubleshooting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge 7\" LCD Screen\u003c\/strong\u003e — Industrial-grade display for user-friendly local operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarsh-Condition Ready\u003c\/strong\u003e — IP66 ingress protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003eKey Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Max. PV Array Size\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Usable PV Input Power\u003c\/td\u003e\n\u003ctd\u003e24 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Input Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range\u003c\/td\u003e\n\u003ctd\u003e200–850 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Current\u003c\/td\u003e\n\u003ctd\u003e40A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Number \/ Max. Input Strings\u003c\/td\u003e\n\u003ctd\u003e2 \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLi-ion \/ Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range\u003c\/td\u003e\n\u003ctd\u003e40–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge\/Discharge Current\u003c\/td\u003e\n\u003ctd\u003e290 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge\/Discharge Current per Port\u003c\/td\u003e\n\u003ctd\u003e175 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication (Battery)\u003c\/td\u003e\n\u003ctd\u003eCAN \/ RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power (Grid)\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Apparent Output Power\u003c\/td\u003e\n\u003ctd\u003e15 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Grid Voltage\u003c\/td\u003e\n\u003ctd\u003e3\/N\/PE, 220V\/380V; 3\/N\/PE, 230V\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Grid Output Current\u003c\/td\u003e\n\u003ctd\u003e22.8A \/ 21.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;0.99 (0.8 leading – 0.8 lagging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDi\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power (Back-up)\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Apparent Output Power (Back-up)\u003c\/td\u003e\n\u003ctd\u003e2× rated power for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack-up Switch Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10ms (single); \u0026lt;20ms (parallel, up to 6 units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Passthrough Current\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Efficiency\u003c\/td\u003e\n\u003ctd\u003e97.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEU Efficiency\u003c\/td\u003e\n\u003ctd\u003e97.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBAT Charged by PV \/ AC Max. Efficiency\u003c\/td\u003e\n\u003ctd\u003e95.0% \/ 94.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Discharged Efficiency\u003c\/td\u003e\n\u003ctd\u003e94.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e430 × 660 × 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Topology\u003c\/td\u003e\n\u003ctd\u003eNon-isolated (PV), Isolated (Battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-25°C ~ +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Emission (typical)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Concept\u003c\/td\u003e\n\u003ctd\u003eIntelligent fan-cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Operation Altitude\u003c\/td\u003e\n\u003ctd\u003e4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 dir=\"ltr\"\u003eProtection Features\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eDC Type II \/ AC Type II (optional) surge protection, output over current protection, insulation resistance monitoring, residual current detection, integrated PV switch, DC reverse-polarity protection, optional Integrated AFCI 2.0, and anti-islanding protection.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eConnectivity \u0026amp; Interfaces\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eMC4 quick-connection PV plugs, screw-terminal battery and AC connections, 7.0\" LCD display with Bluetooth + APP. Standard communication: WiFi + LAN + Bluetooth, CAN-BMS, CAN-Parallel×2, RS485-Meter, RS485, DRM, DI, DO×4. Optional 2G\/3G\/4G connectivity.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eCertifications\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eEN 50549-1\/-10, VDE 4105 \u0026amp; VDE 0124, NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, SriLanka, EN 50438L, Vietnam, MEA, PEA, CEI 0-21; IEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/-2\/-3\/-4\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eIdeal For\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eResidential and commercial three-phase solar-plus-storage systems needing high-capacity, reliable backup power — with smart cloud monitoring and the flexibility to scale into a multi-inverter parallel system.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eSpecifications per manufacturer datasheet (Solis Solarator Series S6-EH3P(5-18)K02-NV-YD-L, Three Phase Low Voltage). Specifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Solis","offers":[{"title":"Default Title","offer_id":43932180316250,"sku":"IN-SO-15K-3PH-PLUS","price":2300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0620\/6580\/3354\/files\/1760318703787_2a8b9e27-deba-4917-b1b5-53b743f086b7.webp?v=1787921661","url":"https:\/\/siw-zim.co.zw\/products\/solis-15kw-3ph-hybrid-inverter","provider":"Siw-Zim","version":"1.0","type":"link"}